DH-RH-01 Computer Control Moving No Rotor Rheometer For Rubber Testing

Product Details
Customization: Available
Type: No Rotor Rheometer For Rubber
Accuracy: 0.1 G (0.1J)
Gold Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

to see all verified strength labels (33)
  • DH-RH-01 Computer Control Moving No Rotor Rheometer For Rubber Testing
  • DH-RH-01 Computer Control Moving No Rotor Rheometer For Rubber Testing
  • DH-RH-01 Computer Control Moving No Rotor Rheometer For Rubber Testing
  • DH-RH-01 Computer Control Moving No Rotor Rheometer For Rubber Testing
  • DH-RH-01 Computer Control Moving No Rotor Rheometer For Rubber Testing
  • DH-RH-01 Computer Control Moving No Rotor Rheometer For Rubber Testing
Find Similar Products

Basic Info.

Model NO.
DH-RH-01
Specimen Clamp
Specimen Clamp
Port Of Gas Supply
Φ8 mm PU Tubing
Delivery Time
3 days
Testing Before Delivery
Yes
After-sale Customer Service
Yes
OEM Service
Yes
Transport Package
Standard Exporting Wooden Package
Trademark
DahoMeter
Origin
Dongguan, Guangdong
HS Code
9027809900
Production Capacity
300 Sets/Month

Product Description

DH-RH-01 Computer Control Moving No Rotor Rheometer For Rubber Testing


Description

The rotorless vulcanometer is the most widely used instrument for controlling rubber quality in the rubber processing industry, rapid inspection, and rubber basic research. It provides accurate data for the optimal rubber compounding formula, accurately measuring the scorch time, the vulcanization time, the vulcanization index and parameters such as maximum and minimum torque.,etc.

 

The vulcanization instrument includes host computer, computer, temperature measurement, temperature control, data acquisition and processing, sensors and electrical interlocking. The measurement and temperature control circuit consists of measurement and control module, platinum resistor, and heater. It can automatically track changes of the power grid and ambient temperature, automatically correct PID parameters, to achieve rapid and accurate temperature control. The data acquisition system and the electromechanical chain complete the automatic detection of the torque signal of the rubber vulcanization process, and automatically display the temperature value and set value in real time. After the vulcanization is completed, the vulcanization curve and the process parameters are automatically processed, calculated, and printed.

 

Show vulcanization time, vulcanization torque. The computer displays the vulcanization process in real time and "temperature" change and the "time-torque" change process can be seen at a glance from above.

 

Characteristics

 

The test instrument has the following characteristics:

a. High accuracy temperature control and wide range. (±0.1°C)

b. Clock programming function. (setting, modification time)

c. Advanced technology switching power supply, wide voltage range.

d. Imported integrated circuits and control components.

e. Meet the requirements of GB/T16584 (Test Rubber Vulcanization Characteristics with Rotorless Vulcanometer) and ISO6502.

 

Powerful microprocessors use high quality imported chips. On the one hand, computers and microprocessors can take signals from the torque sensor and record the signals on the graph. At the same time, the computer and the measurement control module interface exchange data and control the temperature of the mold cavity.

 

The rotorless vulcanometer was designed with a series of interlocking functions, including closing the plastic glass door. If the door is not closed, the mold cannot be closed. Only when the door is closed safely can the mold be closed. Only work can be done.

 

All in all, this type of vulcanizer is more stable, more accurate, cheaper, and more functional than other models. It is the best instrument for testing rubber properties.

 

Specification

 

  • The standard for the implementation of the vulcanization instrument is: ASTM D5289-95 ISO6502-1999(E) GB/T16584-1996
  • Temperature range: room temperature to 200 °C
  • Temperature measurement accuracy: 100 to 200°C, ≤±0.1°C
  • Temperature stability: 100 to 200°C, ≤±0.1°C
  • Setting range: 0 to 200°C; setting minimum unit: 0.1°C
  • Temperature display range: 0 to 200°C; display resolution: 0.1°C
  • Set the time range: 0 to 200 minutes; set the minimum unit: 1 minute
  • Automatic range switching: automatic increase according to actual torque
  • Power: 50HZ, ~220V±10%, 50±1Hz, must be well grounded
  • Compressed air: 0.32Mpa controlled by pneumatic control valve
  • Swing frequency: 100 times/minute (about 1.7HZ)
  • Ambient temperature: normal temperature -40°C, relative humidity less than 80%, no corrosive gas in the air
  • Quality: ≈250kg
  • Power: 2KW
  • Dimensions: 680×630×1100(mm)
DH-RH-01 Computer Control Moving No Rotor Rheometer For Rubber TestingDH-RH-01 Computer Control Moving No Rotor Rheometer For Rubber TestingDH-RH-01 Computer Control Moving No Rotor Rheometer For Rubber Testing

Packaging & Shipping:

DH-RH-01 Computer Control Moving No Rotor Rheometer For Rubber Testing

Company Information

We, Dongguan Hongtuo Instrument Co., Ltd, a China based company, are pleased to introduce ourselves as a notable testing equipments and machines manufacturer.Our company was established in the year 2000 with two primarily motto, which includes complete client satisfaction and to reach top-most position in the international market. The exceptional quality of our products like Gold Tester,Gold Testing Machine,Density Meter,Universal Tensile Testing Machine,Climatic Chamber,Melt Flow Index Tester,Charpy Impact Testing Machine,Tap Density Tester,Abrasion Tester,Ultrasonic Flaw Detector,Surface Roughness Tester and other Laboratory Testing Equipment, etc. is our company's USP. 

DH-RH-01 Computer Control Moving No Rotor Rheometer For Rubber TestingDH-RH-01 Computer Control Moving No Rotor Rheometer For Rubber TestingDH-RH-01 Computer Control Moving No Rotor Rheometer For Rubber Testing

Certification

DH-RH-01 Computer Control Moving No Rotor Rheometer For Rubber Testing


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More